Resumen
We evaluated the efficiency of continuous monitoring of oxyhaemoglobin saturation (SaO2) in the jugular bulb in order to determine its utility in the monitoring and treatment of patients with severe head injury (HI). Sixty-four patients with HI and a Glasgow coma score ≤8 were included in this study. On admission to the intensive care unit, an Opticath® catheter (Abbott Laboratories, North Chicago, IL, USA) was inserted in the right jugular bulb. The maximum jugular venous SaO2 (SjO2) was: 91 (10)(*) for the 36 survivors, 78 (32) for the six vegetative coma patients and 97 (8)(*) for the 22 patients found to be brain dead ((*)p = 0.0009). The minimum SjO2 was: 55 (13)(*) for the survivors, 36 (29)(*)/(**) for the vegetative coma patients ((*)p = 0.001) and 59 (39)(**) for the brain-dead patients ((**)p = 0.01). We conclude that falls in SjO2 may influence the management of HI patients and may help to detect evolution to cerebral ischaemia in these patients. The inclusion of several variables in a logistic regression analysis allows outcome prediction in 95% of these patients.
| Idioma original | Inglés |
|---|---|
| Páginas (desde-hasta) | 182-186 |
| Número de páginas | 5 |
| Publicación | Clinical Intensive Care |
| Volumen | 8 |
| N.º | 4 |
| DOI | |
| Estado | Publicada - 1997 |
| Publicado de forma externa | Sí |
Huella
Profundice en los temas de investigación de 'Severe head injury and jugular bulb venous oxygen saturation monitoring: A pilot study'. En conjunto forman una huella única.Cómo citar
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver