Scintillator pad detector: Very front end electronics. Design and pre-series

S. Luengo, J. Riera, S. Tortella, X. Vilasis-Cardona, D. Gascón, A. Comerma, L. Garrido

Producción científica: Capítulo del libroContribución a congreso/conferenciarevisión exhaustiva

Resumen

The SPD (Scintillator Pad Detector) is a part of LHCb calorimeter which is designed to distinguish electrons and photons for this first level trigger. This detector is a plastic scintillator layer, divided in about 6000 cells of different size to obtain better granularity near the beam. Charged particles will produce, and photons will not, ionisation on the scintillator. This ionisation generates a light pulse that is collected by a Wavelength Shifting (WLS) fibre that is twisted inside the scintillator cell. The light is transmitted through a clear fibre to the readout system. For cost reduction, these 6000 cells are divided in groups using a MAPMT of 64 channels for receiving information in the readout system. The signal outing the SPD PMTs is rather unpredictable as a result of the low photostatistics, 20-30 photoelectrons per MIP, and the response of the WLS fibre, which has low decay time. Then, the signal processing must be performed by first integrating the total charge and later subtracting to avoid pile-up. The SPD Readout system is performed by an ASIC which integrates the signal, makes the pile-up compensation, and compares the level obtained to a programmable threshold (distinguishing electrons and photons), an FPGA which programmes the ASIC thresholds and pile-up subtraction and finally LVDS serializers, in order to send information to the first level trigger system. The design of the VFE unit takes into account not only mechanical constraints, as a result of the little space for the readout electronics but also the radiation quote expected in the environment and the distance between the VFE electronics and the racks were information is sent.

Idioma originalInglés
Título de la publicación alojadaCALORIMETRY IN HIGH ENERGY PHYSICS
Subtítulo de la publicación alojadaXII International Conference
Páginas317-324
Número de páginas8
DOI
EstadoPublicada - 2006
EventoCALORIMETRY IN HIGH ENERGY PHYSICS: XII International Conference - Chicago, IL, Estados Unidos
Duración: 5 jun 20069 jun 2006

Serie de la publicación

NombreAIP Conference Proceedings
Volumen867
ISSN (versión impresa)0094-243X
ISSN (versión digital)1551-7616

Conferencia

ConferenciaCALORIMETRY IN HIGH ENERGY PHYSICS: XII International Conference
País/TerritorioEstados Unidos
CiudadChicago, IL
Período5/06/069/06/06

Huella

Profundice en los temas de investigación de 'Scintillator pad detector: Very front end electronics. Design and pre-series'. En conjunto forman una huella única.

Citar esto