TY - JOUR
T1 - Dispatcher-assisted BLS for lay bystanders
T2 - A pilot study comparing video streaming via smart glasses and telephone instructions
AU - Aranda-García, Silvia
AU - Barrio-Cortes, Jaime
AU - Fernández-Méndez, Felipe
AU - Otero-Agra, Martín
AU - Darné, Marc
AU - Herrera-Pedroviejo, Ernesto
AU - Barcala-Furelos, Roberto
AU - Rodríguez-Núñez, Antonio
N1 - Publisher Copyright: © 2023
PY - 2023/9
Y1 - 2023/9
N2 - Objective: To determine whether dispatcher assistance via smart glasses improves bystander basic life support (BLS) performance compared with standard telephone assistance in a simulated out-of-hospital cardiac arrest (OHCA) scenario. Methods: Pilot study in which 28 lay people randomly assigned to a smart glasses-video assistance (SG-VA) intervention group or a smartphone-audio assistance (SP-AA) control group received dispatcher guidance from a dispatcher to provide BLS in an OHCA simulation. SG-VA rescuers received assistance via a video call with smart glasses (Vuzix, Blade) connected to a wireless network, while SP-AA rescuers received instructions over a smartphone with the speaker function activated. BLS protocol steps, quality of chest compressions, and performance times were compared. Results: Nine of the 14 SG-VA rescuers correctly completed the BLS protocol compared with none of the SP-AA rescuers (p = 0.01). A significantly higher number of SG-VA rescuers successfully opened the airway (13 vs. 5, p = 0.002), checked breathing (13 vs. 8, p = 0.03), correctly positioned the automatic external defibrillator pads (14 vs.6, p = 0.001), and warned bystanders to stay clear before delivering the shock (12 vs. 0, p < 0.001). No significant differences were observed for performance times or chest compression quality. The mean compression rate was 104 compressions per minute in the SG-VA group and 98 compressions per minute in the SP-AA group (p = 0.46); mean depth of compression was 4.5 cm and 4.4 cm (p = 0.49), respectively. Conclusions: Smart glasses could significantly improve dispatcher-assisted bystander performance in an OHCA event. Their potential in real-life situations should be evaluated.
AB - Objective: To determine whether dispatcher assistance via smart glasses improves bystander basic life support (BLS) performance compared with standard telephone assistance in a simulated out-of-hospital cardiac arrest (OHCA) scenario. Methods: Pilot study in which 28 lay people randomly assigned to a smart glasses-video assistance (SG-VA) intervention group or a smartphone-audio assistance (SP-AA) control group received dispatcher guidance from a dispatcher to provide BLS in an OHCA simulation. SG-VA rescuers received assistance via a video call with smart glasses (Vuzix, Blade) connected to a wireless network, while SP-AA rescuers received instructions over a smartphone with the speaker function activated. BLS protocol steps, quality of chest compressions, and performance times were compared. Results: Nine of the 14 SG-VA rescuers correctly completed the BLS protocol compared with none of the SP-AA rescuers (p = 0.01). A significantly higher number of SG-VA rescuers successfully opened the airway (13 vs. 5, p = 0.002), checked breathing (13 vs. 8, p = 0.03), correctly positioned the automatic external defibrillator pads (14 vs.6, p = 0.001), and warned bystanders to stay clear before delivering the shock (12 vs. 0, p < 0.001). No significant differences were observed for performance times or chest compression quality. The mean compression rate was 104 compressions per minute in the SG-VA group and 98 compressions per minute in the SP-AA group (p = 0.46); mean depth of compression was 4.5 cm and 4.4 cm (p = 0.49), respectively. Conclusions: Smart glasses could significantly improve dispatcher-assisted bystander performance in an OHCA event. Their potential in real-life situations should be evaluated.
KW - Cardiopulmonary resuscitation
KW - Dispatcher
KW - OHCA
KW - Smart glasses
UR - http://www.scopus.com/inward/record.url?scp=85164354911&partnerID=8YFLogxK
UR - https://www.webofscience.com/wos/alldb/full-record/WOS:001038947300001
M3 - Article
C2 - 37418840
AN - SCOPUS:85164354911
SN - 0735-6757
VL - 71
SP - 163
EP - 168
JO - American Journal of Emergency Medicine
JF - American Journal of Emergency Medicine
ER -