Abstract
Reference systems for Potentiometrie oxygen sensor in molten 44.5% lead - 55.5% bismuth alloy have been evaluated. Two types of reference systems have been considered: metal / metal oxide and gas with a defined oxygen partial pressure. In/ln2O3 and Sn/SnO have been chosen as a metal / metal oxide reference system, and Pt/air is the gas reference system tested. The sensor performance using all three reference systems has been evaluated using a low oxygen content covering gas (90% Ar + 10% H2 or 99.999% Ar) and air (20% O2). All the tests have been performed in stagnant conditions at 500 °C in an autoclave.
| Original language | English |
|---|---|
| Pages (from-to) | 429-433 |
| Number of pages | 5 |
| Journal | Afinidad |
| Volume | 64 |
| Issue number | 529 |
| Publication status | Published - May 2007 |
Keywords
- Bismuth
- Lead
- Molten metals
- Oxygen sensor
- Reference electrode
Fingerprint
Dive into the research topics of 'Reference systems for oxygen sensors in molten 44.5% lead - 55.5% bismuth alloy'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver