Abstract
A potentiometric In/In2O3 sensor, for measuring oxygen activity in molten 44.5% lead - 55.5% bismuth alloy, has been evaluated. For this purpose, the following experiments have been carried out: evaluation of the sensor performance alternating 99.999% N2 and air (20% O 2), influence of the operating temperature on the sensor response in the range of 400 °C-500 °C, and effects of the sensor depth under LBE and of the material of the tube for the gas inlet on the sensor response. All the tests have been performed in stagnant conditions in an autoclave.
| Original language | English |
|---|---|
| Pages (from-to) | 459-463 |
| Number of pages | 5 |
| Journal | Afinidad |
| Volume | 62 |
| Issue number | 519 |
| Publication status | Published - Sept 2005 |
Keywords
- ADS
- LBE
- Molten metal
- Oxygen activity
- Oxygen sensor
- Sensor performance
Fingerprint
Dive into the research topics of 'Evaluation of electrochemical In/In2O3 oxygen sensor for molten 44.5% lead - 55.5% bismuth alloy'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver