TY - GEN
T1 - Power quality monitoring system under different environmental and electric conditions
AU - Elvira-Ortiz, David A.
AU - Osornio-Rios, Roque A.
AU - Morinigo-Sotelo, Daniel
AU - Rostro-Gonzalez, Horacio
AU - Romero-Troncoso, Rene J.
N1 - Publisher Copyright:
© 2018 IEEE.
PY - 2018/6/8
Y1 - 2018/6/8
N2 - Power quality monitoring has become very important because it allows preventing damages on sensitive equipment. To perform a proper monitoring, it is necessary equipment with certain features: High sampling rate, portability, high-storage capacity, reconfigurability, among others. This paper presents the results of using a proprietary power quality monitoring system in three different scenarios. The system can acquire and store data for extended periods, and then data can be processed to identify power quality disturbances on the electric grid. Results show that the equipment can acquire, store and process data to identify a vast range of power quality disturbances. Moreover, environmental and electric conditions are not equal for the three locations and the equipment is able to properly work regardless these factors.
AB - Power quality monitoring has become very important because it allows preventing damages on sensitive equipment. To perform a proper monitoring, it is necessary equipment with certain features: High sampling rate, portability, high-storage capacity, reconfigurability, among others. This paper presents the results of using a proprietary power quality monitoring system in three different scenarios. The system can acquire and store data for extended periods, and then data can be processed to identify power quality disturbances on the electric grid. Results show that the equipment can acquire, store and process data to identify a vast range of power quality disturbances. Moreover, environmental and electric conditions are not equal for the three locations and the equipment is able to properly work regardless these factors.
KW - Current measurement
KW - Power quality
KW - Total harmonic distortion
KW - Voltage fluctuations
KW - Voltage measurement
UR - http://www.scopus.com/inward/record.url?scp=85049241422&partnerID=8YFLogxK
UR - https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=pure_univeritat_ramon_llull&SrcAuth=WosAPI&KeyUT=WOS:000444771900035&DestLinkType=FullRecord&DestApp=WOS_CPL
U2 - 10.1109/ICHQP.2018.8378846
DO - 10.1109/ICHQP.2018.8378846
M3 - Conference contribution
AN - SCOPUS:85049241422
T3 - Proceedings of International Conference on Harmonics and Quality of Power, ICHQP
SP - 1
EP - 6
BT - ICHQP 2018 - 18th International Conference on Harmonics and Quality of Power
PB - IEEE Computer Society
T2 - 18th International Conference on Harmonics and Quality of Power, ICHQP 2018
Y2 - 13 May 2018 through 16 May 2018
ER -