TY - JOUR
T1 - Novel grafted electrochemical interface for covalent glucose oxidase immobilization using reactive pentafluorophenyl methacrylate
AU - Artigues, Margalida
AU - Oh, Sejin
AU - Gilabert-Porres, Joan
AU - Abellà, Jordi
AU - Borrós, Salvador
AU - Colominas, Sergi
N1 - Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2019/3/1
Y1 - 2019/3/1
N2 - One of the most important factors for the proper functioning of enzymatic electrochemical biosensors is the enzyme immobilization strategy. In this work, glucose oxidase was covalently immobilized using pentafluorophenyl methacrylate (PFM) by applying two different surface modification techniques (plasma polymerization and plasma-grafting). The grafted surface was specifically designed to covalently anchor enzyme molecules. It was observed using QCM-D measurements the PFM plasma-grafted surfaces were able to retain a higher number of active enzyme molecules than the PFM polymerized surfaces. An amperometric glucose biosensor using titanium dioxide nanotubes array (TiO 2 NTAs) modified by PFM plasma-grafted surface was prepared. The resulting biosensor exhibited a fast response and short analysis time (approximately eight minutes per sample). Moreover, this biosensor achieved high sensitivity (9.76 μA mM −1 ) with a linear range from 0.25 to 1.49 mM and a limit of detection (LOD) equal to 0.10 mM of glucose. In addition, the glucose content of 16 different food samples was successfully measured using the developed biosensor. The obtained results were compared with the respective HPLC value and a deviation smaller than 10% was obtained in all the cases. Therefore, the biosensor was able to overcome all possible interferences in the selected samples/matrices.
AB - One of the most important factors for the proper functioning of enzymatic electrochemical biosensors is the enzyme immobilization strategy. In this work, glucose oxidase was covalently immobilized using pentafluorophenyl methacrylate (PFM) by applying two different surface modification techniques (plasma polymerization and plasma-grafting). The grafted surface was specifically designed to covalently anchor enzyme molecules. It was observed using QCM-D measurements the PFM plasma-grafted surfaces were able to retain a higher number of active enzyme molecules than the PFM polymerized surfaces. An amperometric glucose biosensor using titanium dioxide nanotubes array (TiO 2 NTAs) modified by PFM plasma-grafted surface was prepared. The resulting biosensor exhibited a fast response and short analysis time (approximately eight minutes per sample). Moreover, this biosensor achieved high sensitivity (9.76 μA mM −1 ) with a linear range from 0.25 to 1.49 mM and a limit of detection (LOD) equal to 0.10 mM of glucose. In addition, the glucose content of 16 different food samples was successfully measured using the developed biosensor. The obtained results were compared with the respective HPLC value and a deviation smaller than 10% was obtained in all the cases. Therefore, the biosensor was able to overcome all possible interferences in the selected samples/matrices.
KW - Electrochemical biosensor
KW - Glucose oxidase
KW - Hydroxyethyl methacrylate (HEMA)
KW - Plasma modification
KW - QCM-D
KW - Surface engineering
UR - http://www.scopus.com/inward/record.url?scp=85057452679&partnerID=8YFLogxK
UR - https://www.webofscience.com/api/gateway?GWVersion=2&SrcApp=pure_univeritat_ramon_llull&SrcAuth=WosAPI&KeyUT=WOS:000459837800001&DestLinkType=FullRecord&DestApp=WOS_CPL
U2 - 10.1016/j.colsurfb.2018.11.076
DO - 10.1016/j.colsurfb.2018.11.076
M3 - Article
C2 - 30508760
AN - SCOPUS:85057452679
SN - 0927-7765
VL - 175
SP - 1
EP - 9
JO - Colloids and Surfaces B: Biointerfaces
JF - Colloids and Surfaces B: Biointerfaces
ER -