TY - JOUR
T1 - Influence of the initial sludge characteristics and acclimation on the long-term performance of double-compartment acetate-fed microbial fuel cells
AU - Vicari, Fabrizio
AU - Asensio, Yeray
AU - Fernandez-Marchante, Carmen María
AU - Lobato, Justo
AU - Cañizares, Pablo
AU - Scialdone, Onofrio
AU - Rodrigo, Manuel Andrés
N1 - Funding Information:
Financial support from the AEI (Agencia Estatal de Investigación) of the Spanish Ministry of Economy and Competitiveness (MINECO) through project CTQ2013-49748-EXP (Explora Program) is gratefully acknowledged.
Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/9/15
Y1 - 2018/9/15
N2 - In this work, three double-compartment MFCs (DC-MFC) were operated for 1 month in order to compare their performances in terms of wastewater treatment capacity and electricity production and to get information about how this performance is influenced by the start-up procedure. To do this, they underwent different start-up procedures. One of them (aerobic-starved MFC) was inoculated with 100% fresh aerobic sludge, another (anaerobic-starved MFC) using 100% fresh anaerobic sludge, and finally a third one (aerobic-fed MFC) was inoculated using a mixture 10% fresh aerobic sludge and 90% synthetic wastewater (based on acetate). Then, from this start-up, the cells were operated exactly under the same feeding and operation conditions and they underwent the same tests. Results demonstrate that after one month of operation, in DC-MFCs, there are no significant differences in the steady state operation conditions reached because the three cells lead to a very similar treatment capacity, quantified in terms of the COD consumption rate, and to a quite similar value of the current produced. A comprehensive electrochemical characterization informed that the small differences cannot be explained in terms of the different start-up period. This means that the DC-MFC technology is robust enough regarding the inoculation and within systems undergoing the same disturbances, outputs obtained are quite the same, which becomes a very important observation for future works.
AB - In this work, three double-compartment MFCs (DC-MFC) were operated for 1 month in order to compare their performances in terms of wastewater treatment capacity and electricity production and to get information about how this performance is influenced by the start-up procedure. To do this, they underwent different start-up procedures. One of them (aerobic-starved MFC) was inoculated with 100% fresh aerobic sludge, another (anaerobic-starved MFC) using 100% fresh anaerobic sludge, and finally a third one (aerobic-fed MFC) was inoculated using a mixture 10% fresh aerobic sludge and 90% synthetic wastewater (based on acetate). Then, from this start-up, the cells were operated exactly under the same feeding and operation conditions and they underwent the same tests. Results demonstrate that after one month of operation, in DC-MFCs, there are no significant differences in the steady state operation conditions reached because the three cells lead to a very similar treatment capacity, quantified in terms of the COD consumption rate, and to a quite similar value of the current produced. A comprehensive electrochemical characterization informed that the small differences cannot be explained in terms of the different start-up period. This means that the DC-MFC technology is robust enough regarding the inoculation and within systems undergoing the same disturbances, outputs obtained are quite the same, which becomes a very important observation for future works.
KW - Acclimation
KW - Double-compartment microbial fuel cells
KW - Inoculation
KW - Start-up
UR - http://www.scopus.com/inward/record.url?scp=85051118356&partnerID=8YFLogxK
U2 - 10.1016/j.jelechem.2018.08.003
DO - 10.1016/j.jelechem.2018.08.003
M3 - Article
AN - SCOPUS:85051118356
SN - 1572-6657
VL - 825
SP - 1
EP - 7
JO - Journal of Electroanalytical Chemistry
JF - Journal of Electroanalytical Chemistry
ER -